logo
Enviar mensaje
Inicio Noticias

Limitations of Hardness Test

Certificación
Porcelana Dongguan Quality Control Technology Co., Ltd. certificaciones
Porcelana Dongguan Quality Control Technology Co., Ltd. certificaciones
Comentarios de cliente
La pantalla táctil que el probador micro de la dureza de los vickers ha estado instalado hace unas semanas, todo es ACEPTABLE. Gracias por su consejo y servicio excelente.

—— Sr. David Chambers

Las gracias por la entrega rápida y nuestro cliente muy se satisfacen por el probador de la dureza de Rockwell, y esperan más órdenes pronto.

—— Neil Renato

Después de que visitáramos al cliente, finalmente decidían comprar el probador Brinell iBrin-413Z de la dureza, ahora nosotros han instalado la unidad en el sitio de cliente,

—— Fermin Lee

Gracias por los penetradores (diamante  cono 120 grados). Lo conseguimos recientemente y lo probó ya. Penetradores  sea bueno como esperamos. 

—— Dalius Skinulis

Las medidas son buenas para el probador Brinell HBST-3000.

—— Sun Chull Kim

Ey, el probador iVick-484ST de la dureza fue instalado la semana pasada y trabaja bien, las gracias por la ayuda profesional.

—— Sabinian Smith

Estoy alegre informarle que la instalación del probador Brinell de la dureza de SHB-3000C se ha acabado con éxito. ¡Quisiera agradecerle!

—— Robbin

Estoy en línea para chatear ahora
Compañía Noticias
Limitations of Hardness Test
últimas noticias de la compañía sobre Limitations of Hardness Test

 

Limitations of Hardness Test

 

1) Hardness value alone cannot reflect the mechanical properties of different materials.

 

For different materials, if their tensile strength (σb), yield strength (σs, or 00.2), elongation (ε), cross-sectional shrinkage (ψ) and impact toughness (ak) or impact energy (Ak) and other mechanical performance indicators are the same, then in many cases, they can be considered to have the same mechanical behavior under various load conditions and are interchangeable.

 

2) Hardness value alone cannot explain the overall mechanical properties of the workpiece. Some parts with the same material grade can have the same hardness value, but due to different heat treatment processes, their overall mechanical properties may have a large difference.

 

3) Hardness lacks representativeness of mechanical properties under certain conditions. It is precisely because hardness alone cannot fully reflect other mechanical properties of the material, especially the overall mechanical properties. Therefore, under many working conditions, hardness alone is far from enough to characterize the quality of the material.

 

4) It is difficult to fully measure the quality of the material after heat treatment by hardness alone, and it is difficult to judge whether the heat treatment process is appropriate.

 

For example, the hardness of a hypoeutectoid steel part that has been overheated by quenching is the same as that of a part that has been quenched normally, but the impact toughness of the former is much lower than that of the latter.

 

This is because the hardness of the quenched part mainly depends on the carbon content of the martensite, and the impact toughness is closely related to the coarseness of the martensite structure.

 

The martensite of overheated steel is coarse, so its impact toughness is greatly reduced. Another example is that the hardness of hard aluminum that has been obviously overheated is the same as that of the same alloy that has not been overheated, but the strength (especially fatigue strength) and elongation, impact toughness, etc. of the former are significantly lower than those of the latter.

 

This is because the overheated hard aluminum has undergone boundary melting. Due to the above limitations of hardness testing, in the production and research of materials and their parts, in addition to hardness testing, other performance tests must be carried out according to specific circumstances. Of course, this does not affect the widespread application of hardness testing.

 

 

Optical Brinell Rockwell Vickers Multi-functional

 

Hardness Tester HBRV-187.5

 

with 40x Reading Microscope

 

Technical Specifications:

Model HBRV-187.5
Test Force Rockwell 60,100,150kgf (588,980,1471N)
Brinell

306.5,612.9, 1838.8(N)

31.25,62.5,187.5(kgf)

Vickers

294.2, 980.7(N)

30, 100,(kgf)

Hardness Scales Rockwell HRA, HRBW, HRC
Brinell HBW2.5/31.25,HBW2.5/62.5,HBW2.5/187.5,HBW5/62.5
Vickers HV30, HV100
Range of Measurement Rockwell 20-95HRA,10-100HRBW, 20-70HRC
Brinell 5-650HBW
Vickers 5-3000HV
Indenters Diamond Rockwell Indenter, Diamond Vickers Indenter, Ф1.588mm, Ф2.5mm,Ф5mm Tungsten Carbide Brinell Ball Indenter
Magnifications 40X
Dwell Time 1 to 99 seconds
Distance between Indenter Center and Wall 160mm
Available Maximum Height of Specimen Rockwell 200mm
Brinell, Vickers 200mm
Outline Dimension 520*260*780mm
Power Supply AC220V, 50/60Hz
Weight 100kg
 